Support Windows, Linux, Android, Mac.
Support multiple people touching, up to 40 points.
Enter the device control panel → Click the calibration tool → Click the cross cursor in sequence according to the prompts → Save settings.
Adjust the physical position of the bracket and re-fix it, and set the "edge compensation value" in the software.
Check in order: ① Is the power/USB cable loose → ② Is there any stain on the infrared lens → ③ Is there any interference from strong direct light → ④ Is the driver abnormal (reinstall).
Use a microfiber cloth to gently wipe the infrared filter, and corrosive liquids such as alcohol are prohibited.
The whole machine is under warranty for 1 year (not covered by artificial damage or unauthorized disassembly).
Capacitive touch screen,resistive touch screen,IR touch screen
Environmental considerations (temperature and humidity, dust, liquids, chemicals, explosion risk), mounting method, size, resolution, touch technology, brightness, IP rating, interface (serial/USB/Ethernet), processor performance, memory, operating system, supported protocols, certification requirements, and budget.
This depends on the connected device (PLC, PC, instrument). Common interfaces include RS-232/485 (serial), USB Host/Device, Ethernet (10/100/1000M), CAN, Profibus, EtherCAT, and other fieldbus interfaces (expansion modules may be required).
Ensure the mounting surface is flat and sturdy; consider the operating angle and height; allow sufficient space for heat dissipation; avoid direct sunlight; keep away from strong interference sources (motor, inverter); comply with the required protection level (sealing gaskets, conduit connectors); and carefully read the installation manual.
Use it strictly within environmental specifications; avoid excessive mechanical stress (impact, pressure); keep the screen clean (using the correct method); provide a stable power supply; ensure good grounding; and avoid displaying static, high-contrast images for extended periods of time (this may cause burn-in, especially on OLEDs).
Cause
Analysis:
Cause
Analysis:
1. Fault phenomenon: touch deviation, the position touched by the finger does not coincide with the mouse arrow.
Reason analysis: During the last calibration operation, the center position of the bullseye was not touched vertically.
Solution: Re-calibrate.
2. Fault phenomenon: The double tap of the touch screen is not very sensitive.
Reason analysis: The sensitivity of the touch screen is too high.
Solution: find and open the calibration program and reduce the sensitivity.
3. Fault phenomenon: The touch screen suddenly drifts. That is, it suddenly appears that the mouse pointer is not at the position where f is the touch point.
Reason analysis: The touch screen adopts infrared or optical touch technology, which will not cause drift. When the mouse pointer is suddenly not at the position of the finger touch point, it is because the touch effect occurs at the mouse pointer. For example, when a user touches the screen and accidentally touches the screen with the sleeve at the same time, the mouse
pointer will not be at the position where the finger touches the point. This problem is not a drift phenomenon.Solution: During use, pay attention to the cuffs of the clothes, do not touch the touch screen, it is best to touch and write vertically.
4. Fault phenomenon: no response to touch.
Reason analysis: This phenomenon may be caused by the following situations
• a. Touch screen driver installation error.
• b. The computer installs multiple touch drivers of different brands, and the software conflicts.
• c. The operating system of the computer fails.
• e. The interface (USB or serial port) of the computer host fails.
• f. The touch screen signal cable (USB cable or serial cable) is faulty.
Solution: • a. Refer to the touch screen driver installation guide and reinstall the driver.
• b. After uninstalling all the drivers in the computer, reinstall the touch screen driver.
• c. Contact the maintenance personnel of the computer to solve the problem.
• d. Contact the company's after-sales maintenance personnel or the company's local authorized dealer.
5. Fault phenomenon: multi-point cannot be used
Reason analysis: Make sure that the system installed on the computer is a version above WIN7 Home Premium (including this version), XP cannot be multi-point application
Solution: Install WIN7 Home Premium, Professional Edition, Ultimate Edition
1. Check that the power cord is connected to an AC outlet and that the outlet is powered.
2. Check whether the (power) switch key on the panel has been pressed.
3. Check the brightness and contrast settings of the image,
4. Check whether the correct signal source and channel are selected.
1. Adjust the color settings.
2. Check the color system.
1. Find out the interfering electrical appliance and move it away from the product.
If you still have other questions, please contact our relevant personnel.
* Occasionally, image interruption may occur, which may be because the signal frequency of the VGA card does not match the usual standard.
* If the monitor is closed, lines may appear on the screen momentarily, this is normal